- Contact Person : Ms. Jia Kathy
- Company Name : Beijing Aeonmed Co., Ltd.
- Tel : 86-10-83681616-8296
- Fax : 86-10-63718989
- Address : Beijing,Beijing,No.4 Hangfeng Road, Fengtai Science Park, Fengtai District, Beijing,China.
- Country/Region : China
- Zip : 100070
medical anesthesia machine with CE
Features
. Classical multifunctional anaesthesia machine
. Dynamic compensation system for tidal volume
. Volume & pressure ventilation, SIMV mode with flow trigger
. CE marked, meet clinical safety requirement of EU
. Advanced electromagnetic valve ensures accurate tidal volume and compensation
. Waveforms displayed include: P-T, F-T and V-T
. Solid coating and anti-dust smooth surface
Technical Specification
Physical & Environmental Specification
. Dimensions (WxHxD): 824x1382x680mm
. Weight: 110kg (including two vaporizers)
. Storage temperature: -22~+55
. Working temperature: +10~+40
. Storage humidity: ≤93%
Electrical Specification
. Mains: 100-240VA C, 50-60Hz
. Battery: 24VDC, minimum90min
. Power consumption: ≤50W
Pneumatic Specification
. Gas supply: O2, N2O: 0.28-0.6Mpa
. Flowmeters : O2: 0-1L/min; 1-10l/min
N2O:0-1L/min; 1-10L/min
. Gas supply: O2 deficiency alarm
Hypoxic guard system
O2 flush: 35-75L/min
. Working mode: Closed, Semi-closed, Semi-open
. Driven mode: Pneumatically driven and electronically controlled
. Operating mode: Man. / Vent.
. Safety valve: ≤8kpa
Ventilator Specification
. Patient type: Adult, pediatric
. Ventilation modes: IPPV, PCV, SIMV(flow-trigger), Manual
. Setting: Touch key & navigator wheel knob
. Tidal volume: 0-1600ml
. Ventilation frequency: 4-100bmp
. I:E ratio: 2:1-1:8
. Pressure control: 5-60cmH2O
. Ppeep: 0-20cmH2O
. Inspiratory plateau: 0-50%Ti
. Trigger sensitivity: 2-30L/min
. High pressure: 21-80cmH2O
. Low pressure: 0-20cmH2O
. Monitoring: Display: 5.7TFT color screen
Pressure: Paw, Ppeak, Pplat, Pmean
Volume: MV, Vt
Breath rate
Gas: FiO2
Compliance
Graph display: P-T, F-T, V-T waveforms
. Alarm: Pressure: Paw, high/low limit
Volumes: MV high/low limit, Vt high limit
Low O2 supply pressure
Apnea
Self-testing failure
Power failure
Alarm silence: ≤120s
Vaporizer
. Support 2 vaporizer (Selectatec compatible)
. Agent type: Halothane, Enflurane, Isoflurane, Sevoflulrane available.
Beijing Aeonmed: The expert of OR & ICU operation
We’re the leading manufacturer of ventilator, anesthesia machine, operation light, operation table, infusion and syringe pump, pendant etc in China with its products covering more than 120 countries and regions all over the world. For more information, welcome to our website: http://www.aeonmed.com
medical anesthesia machine with CE